Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
96904 | HIGH VOLTAGE ENGINEERING CORP NATVAR |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
FLEX | FLEXIBILITY | FLEXIBLE |
ABJH | TEMP RATING | -10.0 DEG CELSIUS AND 105.0 DEG CELSIUS |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
MATL | MATERIAL | PLASTIC,POLYVINYL CHLORIDE,MIL-I-631,TYPE F,FORM U,SUBFORM UA,GRADE C,CLASS I,CATEGORY I |
AAGT | WALL THICKNESS | 0.010 INCHES MINIMUM AND 0.014 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 800.0 VOLTS PER MIL /0.001 INCH/ |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 1 CATEGORY AND U FORM AND C GRADE AND 22 AWG SIZE AND UA SUBFORM AND 1 CLASS AND F TYPE |
HUES | COLOR | CLEAR |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND OIL RESISTANT |
AARX | INSIDE DIAMETER | 0.025 INCHES MINIMUM AND 0.032 INCHES MAXIMUM |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |